Dynamic balancing measures how a rotor’s mass is distributed around its rotation axis and identifies the correction needed to meet an agreed limit. This guide follows a two-plane impeller test from its first failed readings to final acceptance, and explains how balance grades and residual-unbalance calculations fit into the inspection plan for machined rotating parts.
What Rotor Dynamic Balancing Corrects
Rotor dynamic balancing measures and corrects uneven mass distribution about a rotation axis. On a balancing machine, the rotor is turned in a defined setup so that the required correction amount and angular position can be determined. The aim is an agreed residual unbalance, rather than a claim of perfect balance.
Material variation, blank defects, machining errors and assembly eccentricity can all contribute to rotor unbalance. During service, deposits, uneven wear, distortion or a damaged blade can change the mass distribution again. A rotor that was acceptable when new may therefore need inspection before it is rebalanced.
Unbalance produces a rotating excitation that loads the bearings and supporting structure. For a fixed unbalance, the excitation force increases with the square of rotational speed. Doubling speed gives four times the force; it does not necessarily give four times the measured vibration, because the machine’s stiffness, damping and resonances also affect its response.
Balancing reduces the force associated with mass unbalance. It does not correct a bent shaft, restore a damaged bearing or remove a dimensional runout error. Those conditions must be identified separately, even if they also produce vibration at rotational frequency.
How Rotor Unbalance Determines the Balancing Method
A rotor can be statically balanced and still have a couple unbalance. Checking whether a heavy spot settles at the bottom is therefore insufficient for many rotating assemblies. The location of the unbalance along the axis matters as well as its angular position.
When one correction plane can be sufficient
A narrow rotor with a sufficiently small moment unbalance may be corrected in one plane. This can be a rotating measurement on a balancing machine; single-plane balancing does not necessarily mean a stationary balancing method. The rotor design and acceptance requirement determine whether one plane is adequate.
When two correction planes are needed
For a rotor with rigid behaviour, corrections in two suitable, axially separated planes can control the resultant unbalance and unbalance moment. Greater separation or correction radius may reduce the mass needed for a particular correction, but the available material and structural limits govern where those planes can be placed.
A rotor behaves rigidly for balancing purposes when its unbalance can be corrected without significant speed-dependent bending effects over the relevant range. A long or high-speed rotor may require an assessment of flexible behaviour. ISO 21940-12 addresses that case; a low-speed two-plane result alone does not establish acceptable behaviour through bending critical speeds.
Static unbalance occurs when the center of mass lies off the rotation axis, producing a rotating force. Couple unbalance can exist even when the center of mass lies on the axis. Opposing unbalances at different positions along the rotor create a moment, so a stationary heavy-spot check can miss it. A rotor with both effects has dynamic unbalance. For a rotor with rigid behavior, corrections in two suitable planes can control both the force and the moment.

Selecting a Rotor Balance Quality Grade
Older drawings often refer to ISO 1940-1. Its rigid-rotor balancing requirements were replaced by ISO 21940-11. The current published base edition is ISO 21940-11:2016, with Amendment 1:2022 available. Use the edition and acceptance requirements agreed for the order. The number 1940 was a standard identifier, not its publication year.
The balance quality grade G has units of mm/s. It relates permissible specific residual unbalance to angular velocity. Although the unit resembles vibration velocity, G6.3 does not mean that an installed machine is permitted to vibrate at 6.3 mm/s. Rotor balance acceptance and machine vibration acceptance are separate requirements.
G6.3 is not a universal default for shafts or impellers. The rotor designer or equipment specification should establish the grade or a direct residual-unbalance limit. Bearing loads, the operating speed range and assembly behaviour must be considered. Aerospace rotor specifications can require a different acceptance method from a general industrial grade.
For the same rotor mass and specified speed, a lower G value gives a smaller permissible residual unbalance. The following values are calculated at 3,000 rpm to show the relationship. They are not grade recommendations for particular products.
| Balance grade | Permissible specific unbalance at 3,000 rpm |
|---|---|
| G16 | 50.9 µm |
| G6.3 | 20.1 µm |
| G2.5 | 8.0 µm |
| G1 | 3.2 µm |
Calculating Permissible Residual Unbalance
Keep specific unbalance, residual unbalance and equivalent correction mass separate. Specific unbalance e is unbalance divided by rotor mass. In the units below, 1 µm is numerically equal to 1 g·mm/kg. Neither quantity is the vibration displacement measured at a bearing.
For a rigid-behaviour rotor specified by a G grade, the following equations give the total permissible residual unbalance before its allocation to the relevant tolerance planes. M is rotor mass in kg, G is the numerical grade value in mm/s, and n is the service speed in rpm used by the specification. The speed of a low-speed balancing test can be different from that service speed.
Use the specified plane-allocation method before comparing the result with the machine’s readings. Tolerance planes and the physical planes where mass is corrected may occupy different positions. Their relationship has to be included in the balancing setup.
ω = 2πn / 60
ω is angular velocity in rad/s. The conversion uses n in rpm.
eₚₑᵣ = 1,000G / ω ≈ 9,549G / n
eₚₑᵣ is permissible specific residual unbalance in µm. The factor 9,549 comes from converting rpm and mm to these units.
Uₚₑᵣ = M × eₚₑᵣ
With M in kg and eₚₑᵣ in µm, Uₚₑᵣ is the total permissible residual unbalance in g·mm.
mₑq = Uₚₗₐₙₑ / r
For one plane, Uₚₗₐₙₑ in g·mm divided by the effective correction radius r in mm gives an equivalent mass in g. This converts an unbalance value to a mass at a stated radius.
Calculating a G2.5 limit for a 2 kg impeller
Consider a 2 kg impeller specified at G2.5 and 3,000 rpm. The angular velocity is 2π × 3,000 / 60, or 314.159 rad/s. Dividing 1,000 × 2.5 by that speed gives a permissible specific residual unbalance of 7.958 µm. Multiplying by the 2 kg rotor mass gives 15.92 g·mm, approximately 0.02210 oz·in.
This 15.92 g·mm result is a total before allocation to the relevant tolerance planes. The 1,800 rpm test in the next section has its own approved per-plane limit. An inspector compares the readings with the limit stated in that test procedure.
G2.5 is used for individual major rotating pump components in API 610 inspection practice. Confirm the contract edition, the component or assembly being accepted, and any additional limits in the approved procedure. A G-grade calculation alone does not establish compliance with the complete pump specification.
An Impeller Dynamic Balancing Test
The balancing procedure defines the rotor condition, mounting method, angular reference, permitted correction zones and acceptance limits. The following sequence shows how those controls are applied before the worked inspection example.
Prepare the specified rotor condition
Complete the operations that can materially change mass distribution, or explicitly plan a later balance check. Remove chips and contamination, inspect for damage, and fit the keys, spacers or other items required by the approved test condition.
Locate the rotor and establish the reference
Use the agreed journals, bore or mandrel. Check seating and runout, enter the plane locations and effective radii, and define the zero-angle reference and viewing direction.
Measure the initial unbalance
Run the approved measurement cycle. A calibrated balancing machine determines unbalance from the rotor response. An influence-coefficient field method uses controlled trial masses and the resulting changes in amplitude and phase.
Apply an approved mass correction
Remove material by an allowed drilling, milling or grinding operation, or use an approved retained mass. Follow the instrument’s add-or-remove convention and angle reference. Welding or adhesive attachment requires an approved design and process; it is not a general substitute for a balance weight.
Repeat the run and verify the result
Deburr and clean the corrected region, then measure again. Check the residual result in every required plane. Correct mass, radius, angle and axial position all affect whether the intended vector has been achieved.
Release the documented configuration
Perform the specified repeatability or residual-unbalance verification and retain the report. Protect locating surfaces and record assembly orientation. Subsequent rework, coating, component replacement or disassembly may require another check.
Following a two-plane impeller test at 1,800 rpm
Consider the supplied inspection example. An impeller is mounted on a mandrel and balanced in two planes at a test speed of 1,800 rpm. For this example, the approved procedure sets a separate residual-unbalance limit of 0.001 oz·in in each plane, equivalent to approximately 0.72008 g·mm per plane. The mandrel and its locating condition must be accounted for in the approved setup.
The first run exceeds the limit on both sides. The technician stops the rotor and removes material only from the permitted correction areas. A second measurement shows an improvement, but both planes still exceed the limit. Further approved corrections and measurement runs continue until each plane is within tolerance.
| Run and plane | Correction display | Residual unbalance | Decision |
|---|---|---|---|
| First run, left | −183 mg at 217° | 367 mg·in = 9.3218 g·mm ≈ 0.01295 oz·in | Fail |
| First run, right | −190 mg at 295° | 286 mg·in = 7.2644 g·mm ≈ 0.01009 oz·in | Fail |
| Second run, left | −146 mg at 216° | 292 mg·in = 7.4168 g·mm ≈ 0.01030 oz·in | Fail |
| Second run, right | −134 mg at 297° | 201 mg·in = 5.1054 g·mm ≈ 0.00709 oz·in | Fail |
| Final run, left | −7.32 mg at 296° | 14.6 mg·in = 0.3708 g·mm ≈ 0.000515 oz·in | Pass |
| Final run, right | −10.7 mg at 75° | 16 mg·in = 0.4064 g·mm ≈ 0.000564 oz·in | Pass |
The final left-plane result is about 0.3708 g·mm and the right-plane result is about 0.4064 g·mm. Both are below the 0.72008 g·mm limit for their respective planes, so this example meets the stated residual-unbalance criterion. Release still follows the procedure’s required verification and report checks.
The signed mg readings and angles are the instrument’s correction display. The residual-unbalance values are positive magnitudes expressed as mass multiplied by radius. A negative correction display must be interpreted using that machine’s configured add-or-remove convention and angular reference. It is not itself a negative residual unbalance.
For the conversions above, 1 mg·in equals 0.0254 g·mm, and 1 oz·in equals approximately 720.0779 g·mm. The ounce-inch values are recalculated from the recorded mg·in readings and rounded for display.
Reading the balancing screen in its test context
The supplied screen photograph below shows a separate reading marked NG at 2,049 rpm. It illustrates the correction display and angular reference; it is not the final acceptance record for the 1,800 rpm worked example. Always read a screen result together with its units, test configuration and approved acceptance limit.

Balancing Requirements for Machined Rotating Parts
Machined shafts
For machined shaft components, the bearing journals and mounting interfaces establish the relationship between the component and the balancing axis. Dirt, burrs, journal runout or an eccentric mandrel can change the indicated result. Check those features before trying to correct the mass distribution.
The key condition must also match the assembly plan. ISO 21940-32 defines a half-key convention for balancing keyed shafts and their fitments separately. Record the convention used so that a shaft balanced in one condition is not assembled with a mating component balanced in an incompatible condition.
An eccentric journal on an RV crankshaft is an intentional design feature. It must not be machined away to make the bare part appear balanced. The required phase relationship, counterweights and rotating assembly determine the balancing requirement. Not every reducer shaft needs an individual dynamic-balancing operation.
Integrally bladed rotors
In integrally bladed rotor machining, variations around the disk and blades can contribute to unbalance even when the main bore runs true. An impeller or blisk still needs its specified geometric inspection; a satisfactory balance reading does not verify blade profile, wall thickness or hub integrity.
Correction locations must be approved for that rotor design. A permitted hub or balance land may allow controlled removal, while a blade, fillet or thin rim may not. Do not grind a blade simply because the balancing machine indicates a heavy angular position. Any correction must preserve the required section, surface condition and aerodynamic geometry.
For a shaft carrying an impeller, define whether acceptance applies to the separate components, the assembled rotor or both. Fits, keys, spacers and angular assembly positions can introduce additional unbalance. Component balance results do not automatically prove that the completed assembly meets its limit.

Verifying Rotor Balance Before Release
Confirm the measurement is repeatable
The balancing equipment must be suitable for the rotor’s mass, dimensions, support arrangement and required residual unbalance. Minimum achievable residual unbalance may be specified in g·mm or as specific unbalance in g·mm/kg. It is a machine capability under stated test conditions, not a guarantee for every rotor setup.
Drive components, fixtures, locating errors and the repeatability of loading can affect the result. Where the verification plan requires it, remove and remount or index the rotor to separate fixture effects from rotor unbalance. A very small displayed value is not sufficient if it changes beyond the accepted limit when the setup is repeated.
Interpret vibration before prescribing a correction
A strong once-per-revolution component, often written as 1X, and repeatable phase at a steady operating condition can support an unbalance diagnosis. They do not prove it. Shaft bow, rubbing, alignment errors and other faults can also affect synchronous vibration.
Compare amplitude and phase at the relevant bearings and directions, and examine their response to speed and operating condition. Near a resonance, a small excitation can produce a large response. There is no universal horizontal-to-vertical ratio, axial-to-radial ratio or phase threshold that identifies unbalance on every machine.
Record what was accepted
A balance report should identify the part or assembly, drawing revision, assembled condition and applicable specification. It should record the service speed used for the tolerance, the actual test speed, correction and tolerance plane locations, reference direction, initial readings and final residual unbalance in each required plane. Record the key convention and permitted correction method where relevant.
Before ordering a rotating part, provide those requirements with the model and drawing. Confirm whether dimensional inspection, component balancing, assembly balancing and an installed vibration test are separate acceptance stages. This allows the machining and verification work to be planned without treating one result as proof of all the others.